If your NYC building is over 50,000 gross sq ft and its tax block number ends in 6, it owes a Local Law 87 Energy Efficiency Report (EER) by December 31, 2026. The report combines an energy audit with retro-commissioning of the base building systems. Missing it costs $3,000 in the first year and $5,000 for each year after. Your LL84 benchmarking data is the starting point for the audit.
What is Local Law 87?
Local Law 87 is the energy audit and retro-commissioning law, one of the original Greener, Greater Buildings Plan laws, alongside LL84 benchmarking. Once every ten years, large buildings must:
- Have an energy audit done. A qualified auditor reviews how the building uses energy and identifies upgrades, with estimated costs and savings.
- Retro-commission the base building systems. A commissioning agent tests and tunes heating, cooling, ventilation, hot water, controls and lighting so they work as designed. The fixes found during retro-commissioning must be made.
- File the results as an Energy Efficiency Report with DOB.
Which buildings are due in 2026?
LL87 applies to buildings over 50,000 gross sq ft. That is a higher threshold than LL84’s 25,000 sq ft, so not every building that benchmarks owes an audit. It also covers two or more buildings on one tax lot, or condo buildings under one board, over 100,000 sq ft combined.
Your filing year is set by the last digit of your tax block number:
| Tax block ends in | EER due |
|---|---|
| 6 | December 31, 2026 |
| 7 | December 31, 2027 |
| 8 | December 31, 2028 |
| 9 | December 31, 2029 |
| 0 | December 31, 2030 |
The block number is the middle five digits of your BBL. For BBL 3-01236-0015, the block is 01236, which ends in 6, so the report is due this year.
What happens if you miss it
| Late by | Penalty |
|---|---|
| First year | $3,000 |
| Each additional year | $5,000 |
Since December 15, 2025, LL87 penalties are paid in DOB NOW: Safety, the same system used for benchmarking violations.
The bigger cost is lost time. The audit and retro-commissioning findings are the roadmap for Local Law 97. A building that skips them is planning its 2030 emissions strategy without data.
How LL84 benchmarking data feeds the audit
Benchmarking and LL87 use the same raw material: your building’s utility history.
- Energy use baseline. The auditor starts from the same whole-building energy data you file in Portfolio Manager each year. If that data is incomplete, for example missing tenant meters or fuel oil, the audit’s savings estimates will be wrong.
- ENERGY STAR score and EUI. The audit compares your building with similar buildings. Your benchmarking score is the quickest way to see whether you are a typical building or an outlier worth investigating.
- Consistency with LL97. The audit’s recommended upgrades are what you’ll model for your LL97 emissions limits. If your benchmarking, audit and LL97 numbers don’t match, one of them is wrong.
If you’re due this year, start by downloading your last three years of Portfolio Manager data and checking it for gaps before the auditor arrives.
Is there still time before December 31?
It’s tight but doable for many buildings, if you start now:
- This week: confirm the building is due (block ending in 6, over 50,000 sq ft, on the Covered Buildings List for LL87).
- Within two weeks: hire a qualified energy auditor and retro-commissioning agent. Book site visits and gather drawings, equipment lists and the last 24 months of utility bills.
- Weeks 3–6: site audit, functional testing and the retro-commissioning fixes.
- Before December 31: the professionals prepare and file the EER.
If the timing can’t work, ask about an extension before the deadline. DOB allows extension requests in limited circumstances. The 2025 cohort, for example, had until March 31, 2026 to file a report or an extension request. Don’t count on one without checking current DOB guidance.
Frequently asked questions
Who can perform an LL87 audit?
The energy audit and retro-commissioning must be done by professionals with the credentials DOB requires, such as a licensed engineer or a certified energy auditor or commissioning agent. Check credentials before you sign.
Do we have to make the upgrades the audit recommends?
The audit’s capital upgrade recommendations are not mandatory under LL87. The retro-commissioning fixes are required. In practice, the audit upgrades often become your LL97 compliance plan.
We’re under 50,000 sq ft. Does LL87 apply?
Generally no, though LL84 benchmarking still does if you’re over 25,000 sq ft.
Is LL87 the same as an LL97 report?
No. LL87 is a once-a-decade audit and tune-up. LL97 is an annual emissions report against your building’s carbon limit.
Due this year?
The Cotocon Group’s engineers handle LL87 energy audits and retro-commissioning in-house and can tell you within a day whether a December 31 filing is realistic for your building.